Predicted complex interactions

CCL15_HUMAN + CCR10

SUMMARY
Chemokine
CCL15_HUMAN View chemokine entry
Chemokine organism
Homo sapiens
Partner
CCR10 View partner entry
Partner description
UniProt: P46092; Gene: ccr10_human; Family: Chemokine
Interactions detected
124

3D VIEW
Powered by NGL viewer
Model confidence legend
  • Very high confidence (pLDDT > 90)
  • High confidence (70 ≤ pLDDT < 90)
  • Low confidence (50 ≤ pLDDT < 70)
  • Very low confidence (pLDDT < 50)
RESIDUE CONTACTS

Residues are ordered by chemokine position and interaction type. Use the viewer controls to highlight contacting residues.

Download contacts (CSV)
Chemokine residue CCN Partner residue GPCRdb generic Interaction
LEU 17 NTc.Cm36 GLN 201 - Hydrophobic
LEU 17 NTc.Cm36 GLN 201 - VdWContact
LEU 17 NTc.Cm36 LEU 275 6.63x63 Hydrophobic
GLU 18 NTc.Cm35 LEU 274 6.62x62 Hydrophobic
GLU 18 NTc.Cm35 LEU 274 6.62x62 VdWContact
GLU 18 NTc.Cm35 ALA 277 6.65x65 Hydrophobic
GLU 18 NTc.Cm35 ALA 277 6.65x65 VdWContact
ASN 19 NTc.Cm34 LYS 204 5.35x36 HBAcceptor
ASN 19 NTc.Cm34 LYS 204 5.35x36 VdWContact
ASN 19 NTc.Cm34 LEU 274 6.62x62 VdWContact
PRO 20 NTc.Cm33 PHE 195 - Hydrophobic
PRO 20 NTc.Cm33 PHE 195 - VdWContact
PRO 20 NTc.Cm33 LYS 204 5.35x36 Hydrophobic
PRO 20 NTc.Cm33 LYS 204 5.35x36 VdWContact
PRO 20 NTc.Cm33 ALA 208 5.39x40 Hydrophobic
PRO 20 NTc.Cm33 ALA 208 5.39x40 VdWContact
PRO 20 NTc.Cm33 LEU 274 6.62x62 Hydrophobic
PRO 20 NTc.Cm33 LEU 274 6.62x62 VdWContact
VAL 21 NTc.Cm32 ASP 270 6.58x58 VdWContact
VAL 21 NTc.Cm32 LEU 274 6.62x62 Hydrophobic
VAL 21 NTc.Cm32 LEU 274 6.62x62 VdWContact
VAL 22 NTc.Cm31 PRO 175 4.59x60 Hydrophobic
VAL 22 NTc.Cm31 LEU 193 45.52x52 Hydrophobic
VAL 22 NTc.Cm31 LEU 193 45.52x52 VdWContact
VAL 22 NTc.Cm31 PHE 195 - Hydrophobic
VAL 22 NTc.Cm31 PHE 195 - VdWContact
VAL 22 NTc.Cm31 GLN 211 5.42x43 VdWContact
LEU 23 NTc.Cm30 PHE 124 3.36x36 Hydrophobic
LEU 23 NTc.Cm30 HIS 125 3.37x37 Hydrophobic
LEU 23 NTc.Cm30 HIS 125 3.37x37 VdWContact
LEU 23 NTc.Cm30 GLN 211 5.42x43 HBDonor
LEU 23 NTc.Cm30 GLN 211 5.42x43 VdWContact
LEU 23 NTc.Cm30 PHE 216 5.47x47 Hydrophobic
LEU 23 NTc.Cm30 PHE 216 5.47x47 VdWContact
LEU 23 NTc.Cm30 TYR 263 6.51x51 Hydrophobic
LEU 23 NTc.Cm30 TYR 263 6.51x51 VdWContact
LEU 23 NTc.Cm30 LEU 267 6.55x55 Hydrophobic
ASN 24 NTc.Cm29 LEU 193 45.52x52 VdWContact
SER 25 NTc.Cm28 SER 117 3.29x29 HBAcceptor
SER 25 NTc.Cm28 SER 117 3.29x29 VdWContact
SER 25 NTc.Cm28 TYR 120 3.32x32 VdWContact
PHE 26 NTc.Cm27 GLN 44 1.35x35 VdWContact
PHE 26 NTc.Cm27 ALA 98 2.60x60 Hydrophobic
PHE 26 NTc.Cm27 ALA 98 2.60x60 VdWContact
PHE 26 NTc.Cm27 TRP 106 23.50x50 Hydrophobic
PHE 26 NTc.Cm27 ILE 116 3.28x28 Hydrophobic
PHE 26 NTc.Cm27 ILE 116 3.28x28 VdWContact
PHE 26 NTc.Cm27 CYS 191 45.50x50 Hydrophobic
HIS 27 NTc.Cm26 LEU 292 7.35x34 Hydrophobic
HIS 27 NTc.Cm26 LEU 292 7.35x34 VdWContact
HIS 27 NTc.Cm26 LEU 293 7.36x35 VdWContact
PHE 28 NTc.Cm25 GLN 37 - Hydrophobic
PHE 28 NTc.Cm25 GLN 37 - VdWContact
PHE 28 NTc.Cm25 ARG 190 - PiCation
PHE 28 NTc.Cm25 ARG 190 - VdWContact
ALA 29 NTc.Cm24 LYS 33 - Hydrophobic
ALA 29 NTc.Cm24 VAL 36 - Hydrophobic
ALA 29 NTc.Cm24 VAL 36 - VdWContact
ALA 29 NTc.Cm24 GLN 37 - HBAcceptor
ALA 29 NTc.Cm24 ASP 289 7.32x31 Hydrophobic
ALA 30 NTc.Cm23 LYS 33 - HBAcceptor
ALA 30 NTc.Cm23 LYS 33 - VdWContact
ALA 30 NTc.Cm23 ARG 185 - VdWContact
ASP 31 NTc.Cm22 LEU 30 - Hydrophobic
ASP 31 NTc.Cm22 CYS 31 - VdWContact
ASP 31 NTc.Cm22 LYS 33 - HBAcceptor
ASP 31 NTc.Cm22 LYS 33 - VdWContact
ASP 31 NTc.Cm22 GLN 37 - HBAcceptor
ASP 31 NTc.Cm22 GLN 37 - VdWContact
ASP 31 NTc.Cm22 ARG 185 - Anionic
ASP 31 NTc.Cm22 ARG 185 - HBAcceptor
ASP 31 NTc.Cm22 ARG 185 - VdWContact
CYS 32 NTc.Cm21 LEU 30 - VdWContact
CYS 32 NTc.Cm21 CYS 31 - HBAcceptor
CYS 32 NTc.Cm21 CYS 31 - VdWContact
CYS 32 NTc.Cm21 LYS 33 - Anionic
CYS 32 NTc.Cm21 LYS 33 - VdWContact
THR 34 NTc.Cm19 CYS 31 - Hydrophobic
TYR 36 NTc.Cm17 PRO 28 - VdWContact
ILE 37 NTc.Cm16 TYR 22 - Hydrophobic
ILE 37 NTc.Cm16 TYR 22 - VdWContact
ILE 37 NTc.Cm16 PRO 28 - Hydrophobic
ILE 37 NTc.Cm16 PRO 28 - VdWContact
SER 38 NTc.Cm15 GLU 25 - HBDonor
SER 38 NTc.Cm15 GLU 25 - VdWContact
PRO 42 NTc.Cm11 TYR 22 - Hydrophobic
PRO 42 NTc.Cm11 TYR 22 - VdWContact
LEU 45 NTc.Cm8 GLU 19 - Hydrophobic
LEU 45 NTc.Cm8 GLU 19 - VdWContact
LEU 45 NTc.Cm8 TYR 22 - Hydrophobic
PHE 50 NTc.Cm3 ARG 185 - Hydrophobic
PHE 50 NTc.Cm3 ARG 185 - VdWContact
SER 54 CX.5 LEU 193 45.52x52 HBDonor
SER 54 CX.5 LEU 193 45.52x52 VdWContact
SER 54 CX.5 ILE 194 - VdWContact
SER 54 CX.5 PHE 195 - HBAcceptor
SER 54 CX.5 PHE 195 - VdWContact
LYS 58 cxb1.6 GLU 279 - Cationic
LYS 58 cxb1.6 GLU 279 - HBDonor
LYS 58 cxb1.6 GLU 279 - Hydrophobic
LYS 58 cxb1.6 GLU 279 - VdWContact
ILE 62 cxb1.11 LEU 30 - Hydrophobic
ILE 62 cxb1.11 LEU 30 - VdWContact
LYS 67 B1.2 GLU 19 - Cationic
LYS 67 B1.2 GLU 19 - HBDonor
LYS 67 B1.2 GLU 19 - VdWContact
GLN 70 B1.5 LEU 30 - Hydrophobic
GLN 70 B1.5 LEU 30 - VdWContact
GLN 70 B1.5 TYR 32 - HBAcceptor
GLN 70 B1.5 TYR 32 - VdWContact
VAL 71 B1.6 LEU 27 - Hydrophobic
VAL 71 B1.6 LEU 27 - VdWContact
CYS 72 B1.7 PRO 28 - Hydrophobic
CYS 72 B1.7 PRO 28 - VdWContact
PRO 75 b1b2.9 GLU 197 - VdWContact
GLN 81 B2.1 GLU 197 - HBDonor
GLN 81 B2.1 GLU 197 - VdWContact
TYR 90 b2b3.12 GLN 184 - VdWContact
SER 91 B3.1 GLN 184 - VdWContact
ILE 92 B3.2 GLN 184 - HBAcceptor
ILE 92 B3.2 GLN 184 - HBDonor
ILE 92 B3.2 GLN 184 - Hydrophobic
ILE 92 B3.2 GLN 184 - VdWContact
ILE 92 B3.2 GLY 187 - VdWContact