Predicted complex interactions

CCL13_HUMAN + ACKR2

SUMMARY
Chemokine
CCL13_HUMAN View chemokine entry
Chemokine organism
Homo sapiens
Partner
ACKR2 View partner entry
Partner description
UniProt: O00590; Gene: ackr2_human; Family: Chemokine
Interactions detected
124

3D VIEW
Powered by NGL viewer
Model confidence legend
  • Very high confidence (pLDDT > 90)
  • High confidence (70 ≤ pLDDT < 90)
  • Low confidence (50 ≤ pLDDT < 70)
  • Very low confidence (pLDDT < 50)
RESIDUE CONTACTS

Residues are ordered by chemokine position and interaction type. Use the viewer controls to highlight contacting residues.

Download contacts (CSV)
Chemokine residue CCN Partner residue GPCRdb generic Interaction
ASN 2 NTc.Cm32 ASP 198 - VdWContact
PRO 3 NTc.Cm31 ASP 198 - VdWContact
PRO 3 NTc.Cm31 PHE 199 - HBAcceptor
PRO 3 NTc.Cm31 PHE 199 - Hydrophobic
PRO 3 NTc.Cm31 PHE 199 - VdWContact
PRO 3 NTc.Cm31 GLY 200 - VdWContact
PRO 3 NTc.Cm31 GLY 201 - VdWContact
GLN 4 NTc.Cm30 HIS 186 - Hydrophobic
GLN 4 NTc.Cm30 HIS 196 45.51x51 Hydrophobic
GLN 4 NTc.Cm30 HIS 196 45.51x51 VdWContact
GLN 4 NTc.Cm30 ALA 197 45.52x52 VdWContact
GLN 4 NTc.Cm30 ASP 198 - VdWContact
GLY 5 NTc.Cm29 HIS 196 45.51x51 VdWContact
GLY 5 NTc.Cm29 ALA 197 45.52x52 HBAcceptor
GLY 5 NTc.Cm29 ALA 197 45.52x52 VdWContact
GLY 5 NTc.Cm29 PHE 199 - VdWContact
LEU 6 NTc.Cm28 PHE 199 - Hydrophobic
LEU 6 NTc.Cm28 PHE 199 - VdWContact
LEU 6 NTc.Cm28 LYS 207 5.35x36 Hydrophobic
LEU 6 NTc.Cm28 LEU 210 5.38x39 Hydrophobic
LEU 6 NTc.Cm28 LEU 210 5.38x39 VdWContact
LEU 6 NTc.Cm28 ARG 211 5.39x40 Hydrophobic
LEU 6 NTc.Cm28 ARG 211 5.39x40 VdWContact
ALA 7 NTc.Cm27 SER 121 3.29x29 VdWContact
ALA 7 NTc.Cm27 VAL 183 4.64x65 Hydrophobic
ALA 7 NTc.Cm27 VAL 183 4.64x65 VdWContact
ALA 7 NTc.Cm27 HIS 196 45.51x51 VdWContact
ALA 7 NTc.Cm27 ALA 197 45.52x52 HBDonor
ALA 7 NTc.Cm27 ALA 197 45.52x52 Hydrophobic
ALA 7 NTc.Cm27 ALA 197 45.52x52 VdWContact
GLN 8 NTc.Cm26 TRP 102 2.60x60 Hydrophobic
GLN 8 NTc.Cm26 TRP 102 2.60x60 VdWContact
GLN 8 NTc.Cm26 CYS 195 45.50x50 VdWContact
GLN 8 NTc.Cm26 HIS 196 45.51x51 Hydrophobic
GLN 8 NTc.Cm26 HIS 196 45.51x51 VdWContact
PRO 9 NTc.Cm25 TRP 102 2.60x60 Hydrophobic
PRO 9 NTc.Cm25 TRP 102 2.60x60 VdWContact
PRO 9 NTc.Cm25 TYR 124 3.32x32 Hydrophobic
PRO 9 NTc.Cm25 GLU 298 7.39x38 VdWContact
PRO 9 NTc.Cm25 PHE 302 7.43x42 Hydrophobic
PRO 9 NTc.Cm25 PHE 302 7.43x42 VdWContact
ASP 10 NTc.Cm24 ARG 211 5.39x40 Anionic
ASP 10 NTc.Cm24 TYR 266 6.51x51 HBAcceptor
ASP 10 NTc.Cm24 TYR 266 6.51x51 VdWContact
ASP 10 NTc.Cm24 LEU 294 7.35x34 Hydrophobic
ASP 10 NTc.Cm24 LEU 294 7.35x34 VdWContact
ASP 10 NTc.Cm24 GLU 298 7.39x38 HBDonor
ASP 10 NTc.Cm24 GLU 298 7.39x38 VdWContact
ALA 11 NTc.Cm23 LEU 49 1.35x35 Hydrophobic
ALA 11 NTc.Cm23 GLN 295 7.36x35 Hydrophobic
ALA 11 NTc.Cm23 GLN 295 7.36x35 VdWContact
ALA 11 NTc.Cm23 GLU 298 7.39x38 HBDonor
ALA 11 NTc.Cm23 GLU 298 7.39x38 VdWContact
LEU 12 NTc.Cm22 TYR 53 1.39x39 Hydrophobic
LEU 12 NTc.Cm22 TRP 102 2.60x60 Hydrophobic
LEU 12 NTc.Cm22 VAL 106 2.64x64 Hydrophobic
LEU 12 NTc.Cm22 VAL 106 2.64x64 VdWContact
VAL 14 NTc.Cm20 LYS 38 1.24x24 Hydrophobic
VAL 14 NTc.Cm20 VAL 41 1.27x27 Hydrophobic
VAL 14 NTc.Cm20 VAL 42 1.28x28 Hydrophobic
VAL 14 NTc.Cm20 ASP 291 7.32x31 Hydrophobic
VAL 14 NTc.Cm20 ASP 291 7.32x31 VdWContact
VAL 14 NTc.Cm20 GLN 295 7.36x35 VdWContact
PRO 15 NTc.Cm19 LYS 38 1.24x24 VdWContact
SER 16 NTc.Cm18 LYS 38 1.24x24 HBAcceptor
SER 16 NTc.Cm18 LYS 38 1.24x24 VdWContact
THR 17 NTc.Cm17 LEU 35 - Hydrophobic
THR 17 NTc.Cm17 CYS 36 - VdWContact
THR 17 NTc.Cm17 ARG 37 - Hydrophobic
CYS 18 NTc.Cm16 CYS 36 - HBAcceptor
CYS 18 NTc.Cm16 CYS 36 - HBDonor
CYS 18 NTc.Cm16 CYS 36 - VdWContact
PHE 20 NTc.Cm14 CYS 36 - Hydrophobic
PHE 20 NTc.Cm14 CYS 36 - VdWContact
PHE 20 NTc.Cm14 LEU 276 6.61x61 Hydrophobic
PHE 20 NTc.Cm14 CYS 284 7.25x24 Hydrophobic
PHE 20 NTc.Cm14 SER 287 7.28x27 VdWContact
THR 21 NTc.Cm13 MET 34 - VdWContact
PHE 22 NTc.Cm12 MET 34 - VdWContact
SER 23 NTc.Cm11 TYR 27 - HBAcceptor
SER 23 NTc.Cm11 TYR 27 - VdWContact
SER 23 NTc.Cm11 VAL 31 - VdWContact
LYS 25 NTc.Cm9 TYR 27 - HBDonor
LYS 25 NTc.Cm9 TYR 27 - Hydrophobic
LYS 25 NTc.Cm9 TYR 27 - VdWContact
ILE 27 NTc.Cm7 TYR 24 - Hydrophobic
ILE 27 NTc.Cm7 TYR 24 - VdWContact
SER 28 NTc.Cm6 TYR 24 - HBAcceptor
SER 28 NTc.Cm6 TYR 24 - HBDonor
SER 28 NTc.Cm6 TYR 24 - VdWContact
ARG 31 NTc.Cm3 SER 21 - VdWContact
ARG 31 NTc.Cm3 TYR 24 - CationPi
ARG 31 NTc.Cm3 TYR 24 - Hydrophobic
ARG 31 NTc.Cm3 TYR 24 - VdWContact
THR 38 cxb1.5 HIS 202 5.30x31 HBDonor
THR 38 cxb1.5 HIS 202 5.30x31 VdWContact
SER 40 cxb1.7 HIS 202 5.30x31 VdWContact
CYS 42 cxb1.10 HIS 202 5.30x31 VdWContact
PRO 43 cxb1.11 LEU 276 6.61x61 Hydrophobic
PRO 43 cxb1.11 ASP 277 6.62x62 VdWContact
GLN 44 cxb1.14 HIS 202 5.30x31 VdWContact
GLN 44 cxb1.14 GLN 279 6.64x64 VdWContact
LYS 45 cxb1.15 HIS 202 5.30x31 Hydrophobic
LYS 45 cxb1.15 HIS 202 5.30x31 VdWContact
ILE 48 B1.2 LEU 35 - Hydrophobic
THR 51 B1.5 LEU 28 - Hydrophobic
LEU 53 B1.7 TYR 25 - Hydrophobic
LEU 53 B1.7 TYR 25 - VdWContact
LYS 55 b1b2.6 LEU 28 - Hydrophobic
LYS 55 b1b2.6 ASP 29 - Cationic
LYS 55 b1b2.6 ASP 29 - HBDonor
LYS 55 b1b2.6 ASP 29 - VdWContact
LYS 55 b1b2.6 ALA 32 - Hydrophobic
GLU 56 b1b2.9 ALA 32 - VdWContact
GLU 56 b1b2.9 LEU 35 - Hydrophobic
GLU 56 b1b2.9 LEU 35 - VdWContact
GLU 56 b1b2.9 ARG 37 - Anionic
GLU 56 b1b2.9 ARG 37 - HBAcceptor
GLU 56 b1b2.9 ARG 37 - VdWContact
ILE 57 b1b2.10 LEU 28 - Hydrophobic
ILE 57 b1b2.10 LEU 28 - VdWContact
ILE 57 b1b2.10 VAL 31 - Hydrophobic
ILE 57 b1b2.10 VAL 31 - VdWContact
CYS 58 b1b2.12 MET 34 - Hydrophobic