Predicted complex interactions

CXCL5_HUMAN + CXCR2

SUMMARY
Chemokine
CXCL5_HUMAN View chemokine entry
Chemokine organism
Homo sapiens
Partner
CXCR2 View partner entry
Partner description
UniProt: P25025; Gene: cxcr2_human; Family: Chemokine
Interactions detected
140

3D VIEW
Powered by NGL viewer
Model confidence legend
  • Very high confidence (pLDDT > 90)
  • High confidence (70 ≤ pLDDT < 90)
  • Low confidence (50 ≤ pLDDT < 70)
  • Very low confidence (pLDDT < 50)
RESIDUE CONTACTS

Residues are ordered by chemokine position and interaction type. Use the viewer controls to highlight contacting residues.

Download contacts (CSV)
Chemokine residue CCN Partner residue GPCRdb generic Interaction
ALA 5 NTc.Cm44 VAL 192 - VdWContact
ALA 5 NTc.Cm44 SER 193 - VdWContact
ALA 6 NTc.Cm43 VAL 192 - VdWContact
ALA 6 NTc.Cm43 SER 193 - HBAcceptor
ALA 6 NTc.Cm43 SER 193 - VdWContact
VAL 7 NTc.Cm42 SER 107 2.63x63 VdWContact
LEU 8 NTc.Cm41 PRO 41 - Hydrophobic
LEU 8 NTc.Cm41 PRO 41 - VdWContact
LEU 8 NTc.Cm41 VAL 192 - Hydrophobic
LEU 8 NTc.Cm41 VAL 192 - VdWContact
ARG 9 NTc.Cm40 TYR 197 45.51x51 VdWContact
ARG 9 NTc.Cm40 TYR 267 6.51x51 VdWContact
ARG 9 NTc.Cm40 LEU 296 7.35x34 VdWContact
ARG 9 NTc.Cm40 ASP 297 7.36x35 Cationic
ARG 9 NTc.Cm40 GLU 300 7.39x38 Cationic
ARG 9 NTc.Cm40 GLU 300 7.39x38 VdWContact
GLU 10 NTc.Cm39 TYR 197 45.51x51 VdWContact
GLU 10 NTc.Cm39 ARG 208 5.35x36 Anionic
GLU 10 NTc.Cm39 ARG 208 5.35x36 HBAcceptor
GLU 10 NTc.Cm39 ARG 208 5.35x36 VdWContact
GLU 10 NTc.Cm39 ARG 212 5.39x40 Anionic
GLU 10 NTc.Cm39 ARG 278 6.62x62 Anionic
GLU 10 NTc.Cm39 ARG 278 6.62x62 HBAcceptor
GLU 10 NTc.Cm39 ARG 278 6.62x62 VdWContact
GLU 10 NTc.Cm39 LEU 296 7.35x34 Hydrophobic
LEU 11 NTc.Cm38 VAL 187 - Hydrophobic
LEU 11 NTc.Cm38 VAL 192 - Hydrophobic
LEU 11 NTc.Cm38 TYR 197 45.51x51 HBAcceptor
LEU 11 NTc.Cm38 TYR 197 45.51x51 HBDonor
LEU 11 NTc.Cm38 TYR 197 45.51x51 Hydrophobic
LEU 11 NTc.Cm38 TYR 197 45.51x51 VdWContact
LEU 11 NTc.Cm38 ARG 278 6.62x62 HBAcceptor
LEU 11 NTc.Cm38 ARG 278 6.62x62 VdWContact
ARG 12 NTc.Cm37 ASP 274 6.58x58 Cationic
ARG 12 NTc.Cm37 ASP 274 6.58x58 HBDonor
ARG 12 NTc.Cm37 ASP 274 6.58x58 VdWContact
ARG 12 NTc.Cm37 MET 277 6.61x61 VdWContact
ARG 12 NTc.Cm37 GLU 284 - Cationic
ARG 12 NTc.Cm37 ASP 293 7.32x31 Cationic
ARG 12 NTc.Cm37 ASP 293 7.32x31 HBDonor
ARG 12 NTc.Cm37 ASP 293 7.32x31 VdWContact
CYS 13 NTc.Cm36 ARG 289 7.28x27 HBAcceptor
CYS 13 NTc.Cm36 ARG 289 7.28x27 VdWContact
VAL 14 NTc.Cm35 PRO 38 - Hydrophobic
VAL 14 NTc.Cm35 PRO 38 - VdWContact
VAL 14 NTc.Cm35 CYS 39 - HBAcceptor
VAL 14 NTc.Cm35 CYS 39 - VdWContact
LEU 16 NTc.Cm33 CYS 39 - VdWContact
LEU 16 NTc.Cm33 GLU 284 - Hydrophobic
LEU 16 NTc.Cm33 GLU 284 - VdWContact
LEU 16 NTc.Cm33 ARG 289 7.28x27 VdWContact
GLN 17 NTc.Cm32 ASP 35 - VdWContact
THR 19 NTc.Cm30 LEU 33 - Hydrophobic
THR 19 NTc.Cm30 LEU 33 - VdWContact
THR 19 NTc.Cm30 ALA 36 - Hydrophobic
GLN 20 NTc.Cm29 TYR 23 - VdWContact
HIS 23 NTc.Cm26 LEU 20 - Hydrophobic
HIS 23 NTc.Cm26 LEU 20 - VdWContact
HIS 23 NTc.Cm26 TYR 23 - Hydrophobic
HIS 23 NTc.Cm26 TYR 23 - VdWContact
HIS 23 NTc.Cm26 TYR 25 - Hydrophobic
HIS 23 NTc.Cm26 TYR 25 - PiStacking
HIS 23 NTc.Cm26 TYR 25 - VdWContact
PRO 24 NTc.Cm25 TRP 15 - Hydrophobic
PRO 24 NTc.Cm25 TRP 15 - VdWContact
PRO 24 NTc.Cm25 LEU 20 - Hydrophobic
PRO 24 NTc.Cm25 LEU 20 - VdWContact
LYS 25 NTc.Cm24 TYR 25 - Hydrophobic
ILE 27 NTc.Cm22 MET 6 - Hydrophobic
SER 28 NTc.Cm21 MET 6 - HBAcceptor
SER 28 NTc.Cm21 MET 6 - VdWContact
SER 28 NTc.Cm21 GLU 7 - VdWContact
ASN 29 NTc.Cm20 PHE 4 - VdWContact
LEU 30 NTc.Cm19 ASP 3 - VdWContact
LEU 30 NTc.Cm19 PHE 4 - HBAcceptor
LEU 30 NTc.Cm19 PHE 4 - HBDonor
LEU 30 NTc.Cm19 PHE 4 - Hydrophobic
LEU 30 NTc.Cm19 PHE 4 - VdWContact
LEU 30 NTc.Cm19 MET 6 - Hydrophobic
LEU 30 NTc.Cm19 MET 6 - VdWContact
GLN 31 NTc.Cm18 MET 1 - Hydrophobic
GLN 31 NTc.Cm18 MET 1 - VdWContact
GLN 31 NTc.Cm18 GLU 2 - VdWContact
GLN 31 NTc.Cm18 ASP 3 - VdWContact
VAL 32 NTc.Cm17 MET 1 - VdWContact
VAL 32 NTc.Cm17 GLU 2 - HBAcceptor
VAL 32 NTc.Cm17 GLU 2 - HBDonor
VAL 32 NTc.Cm17 GLU 2 - VdWContact
VAL 32 NTc.Cm17 PHE 4 - Hydrophobic
VAL 32 NTc.Cm17 PHE 4 - VdWContact
PHE 33 NTc.Cm16 MET 1 - Hydrophobic
PHE 33 NTc.Cm16 SER 190 - VdWContact
ILE 35 NTc.Cm14 ASN 202 - Hydrophobic
ILE 35 NTc.Cm14 ASN 202 - VdWContact
PRO 37 NTc.Cm12 VAL 187 - Hydrophobic
PRO 37 NTc.Cm12 TYR 197 45.51x51 Hydrophobic
PRO 37 NTc.Cm12 ASP 199 - Hydrophobic
PRO 37 NTc.Cm12 ASP 199 - VdWContact
PRO 37 NTc.Cm12 THR 204 5.31x32 Hydrophobic
SER 40 NTc.Cm9 ASN 202 - VdWContact
VAL 45 NTc.Cm4 PRO 38 - Hydrophobic
LEU 48 NTc.Cm1 LEU 29 - Hydrophobic
LEU 48 NTc.Cm1 LEU 29 - VdWContact
LYS 49 CX.1 GLU 7 - Cationic
LYS 49 CX.1 GLU 7 - VdWContact
ASN 50 CX.4 LEU 29 - VdWContact
LYS 52 cxb1.1 LEU 29 - Hydrophobic
LYS 52 cxb1.1 LEU 29 - VdWContact
GLU 53 cxb1.2 PRO 38 - Hydrophobic
ILE 54 cxb1.5 LEU 29 - Hydrophobic
ILE 54 cxb1.5 LEU 29 - VdWContact
ILE 54 cxb1.5 LEU 33 - Hydrophobic
ILE 54 cxb1.5 LEU 33 - VdWContact
ILE 54 cxb1.5 ALA 36 - Hydrophobic
ILE 54 cxb1.5 ALA 36 - VdWContact
CYS 55 cxb1.6 ALA 36 - HBDonor
CYS 55 cxb1.6 ALA 36 - VdWContact
PHE 62 B1.1 TRP 15 - Hydrophobic
PHE 62 B1.1 TYR 23 - Hydrophobic
LYS 65 B1.4 PHE 14 - Hydrophobic
LYS 65 B1.4 GLU 18 - Cationic
LYS 65 B1.4 GLU 18 - HBDonor
LYS 65 B1.4 GLU 18 - VdWContact
VAL 66 B1.5 MET 6 - Hydrophobic
VAL 66 B1.5 MET 6 - VdWContact
VAL 66 B1.5 PHE 11 - Hydrophobic
VAL 66 B1.5 PHE 11 - VdWContact
VAL 66 B1.5 TRP 15 - Hydrophobic
VAL 66 B1.5 TRP 15 - VdWContact
LYS 69 b1b2.4 SER 10 - HBDonor
LYS 69 b1b2.4 SER 10 - VdWContact
LYS 69 b1b2.4 PHE 11 - CationPi
LYS 69 b1b2.4 PHE 11 - Hydrophobic
LYS 69 b1b2.4 PHE 11 - VdWContact
LYS 69 b1b2.4 PHE 14 - Hydrophobic
LYS 69 b1b2.4 PHE 14 - VdWContact
ILE 70 b1b2.6 PHE 4 - Hydrophobic
ILE 70 b1b2.6 PHE 4 - VdWContact
ILE 70 b1b2.6 PHE 11 - Hydrophobic
ILE 70 b1b2.6 PHE 11 - VdWContact