Predicted complex interactions

CXCL16_HUMAN + CXCR3

SUMMARY
Chemokine
CXCL16_HUMAN View chemokine entry
Chemokine organism
Homo sapiens
Partner
CXCR3 View partner entry
Partner description
UniProt: P49682; Gene: cxcr3_human; Family: Chemokine
Interactions detected
113

3D VIEW
Powered by NGL viewer
Model confidence legend
  • Very high confidence (pLDDT > 90)
  • High confidence (70 ≤ pLDDT < 90)
  • Low confidence (50 ≤ pLDDT < 70)
  • Very low confidence (pLDDT < 50)
RESIDUE CONTACTS

Residues are ordered by chemokine position and interaction type. Use the viewer controls to highlight contacting residues.

Download contacts (CSV)
Chemokine residue CCN Partner residue GPCRdb generic Interaction
ASN 1 NTc.Cm56 GLN 204 45.51x51 VdWContact
GLU 2 NTc.Cm55 GLN 204 45.51x51 HBAcceptor
GLU 2 NTc.Cm55 GLN 204 45.51x51 Hydrophobic
GLU 2 NTc.Cm55 GLN 204 45.51x51 VdWContact
GLU 2 NTc.Cm55 TYR 205 45.52x52 Hydrophobic
GLU 2 NTc.Cm55 TYR 205 45.52x52 VdWContact
GLU 2 NTc.Cm55 ASN 206 - VdWContact
GLY 3 NTc.Cm54 TYR 205 45.52x52 HBAcceptor
GLY 3 NTc.Cm54 TYR 205 45.52x52 VdWContact
SER 4 NTc.Cm53 TRP 109 2.60x60 VdWContact
SER 4 NTc.Cm53 CYS 203 45.50x50 HBDonor
SER 4 NTc.Cm53 CYS 203 45.50x50 VdWContact
VAL 5 NTc.Cm52 GLY 128 3.29x29 VdWContact
VAL 5 NTc.Cm52 PHE 131 3.32x32 Hydrophobic
VAL 5 NTc.Cm52 PHE 131 3.32x32 VdWContact
VAL 5 NTc.Cm52 TYR 205 45.52x52 Hydrophobic
THR 6 NTc.Cm51 TYR 271 6.51x51 HBDonor
THR 6 NTc.Cm51 TYR 271 6.51x51 Hydrophobic
THR 6 NTc.Cm51 TYR 271 6.51x51 VdWContact
THR 6 NTc.Cm51 VAL 275 6.55x55 Hydrophobic
THR 6 NTc.Cm51 LYS 300 7.35x34 Hydrophobic
THR 6 NTc.Cm51 LYS 300 7.35x34 VdWContact
THR 6 NTc.Cm51 SER 304 7.39x38 VdWContact
GLY 7 NTc.Cm50 LYS 300 7.35x34 VdWContact
GLY 7 NTc.Cm50 SER 301 7.36x35 VdWContact
SER 8 NTc.Cm49 ASP 297 7.32x31 HBDonor
SER 8 NTc.Cm49 ASP 297 7.32x31 VdWContact
SER 8 NTc.Cm49 LYS 300 7.35x34 HBAcceptor
SER 8 NTc.Cm49 LYS 300 7.35x34 VdWContact
CYS 9 NTc.Cm48 ASP 297 7.32x31 Hydrophobic
CYS 9 NTc.Cm48 ASP 297 7.32x31 VdWContact
TYR 10 NTc.Cm47 ASP 112 2.63x63 HBDonor
TYR 10 NTc.Cm47 ASP 112 2.63x63 VdWContact
TYR 10 NTc.Cm47 HIS 202 - Hydrophobic
TYR 10 NTc.Cm47 HIS 202 - PiStacking
GLY 12 NTc.Cm45 HIS 202 - VdWContact
ARG 14 NTc.Cm43 ASP 46 1.25x25 HBDonor
ARG 14 NTc.Cm43 ASP 46 1.25x25 VdWContact
ARG 14 NTc.Cm43 LEU 49 1.28x28 Hydrophobic
ARG 14 NTc.Cm43 LEU 49 1.28x28 VdWContact
ARG 28 NTc.Cm29 ARG 197 - VdWContact
LEU 29 NTc.Cm28 ARG 197 - HBAcceptor
LEU 29 NTc.Cm28 ARG 197 - VdWContact
ARG 30 NTc.Cm27 ARG 197 - VdWContact
LYS 31 NTc.Cm26 ARG 197 - HBAcceptor
LYS 31 NTc.Cm26 ARG 197 - VdWContact
HIS 32 NTc.Cm25 ARG 197 - Hydrophobic
HIS 32 NTc.Cm25 ARG 197 - VdWContact
LEU 33 NTc.Cm24 ARG 197 - VdWContact
ARG 34 NTc.Cm23 HIS 193 - HBDonor
ARG 34 NTc.Cm23 HIS 193 - VdWContact
ARG 38 NTc.Cm19 PRO 42 - VdWContact
ARG 38 NTc.Cm19 GLU 293 7.28x27 HBDonor
ARG 38 NTc.Cm19 GLU 293 7.28x27 VdWContact
ARG 38 NTc.Cm19 SER 294 7.29x28 VdWContact
CYS 39 NTc.Cm18 GLN 45 1.24x24 HBAcceptor
CYS 39 NTc.Cm18 GLN 45 1.24x24 VdWContact
CYS 39 NTc.Cm18 SER 294 7.29x28 VdWContact
CYS 39 NTc.Cm18 ASP 297 7.32x31 Hydrophobic
CYS 39 NTc.Cm18 ASP 297 7.32x31 VdWContact
LEU 40 NTc.Cm17 GLN 45 1.24x24 VdWContact
LEU 40 NTc.Cm17 SER 294 7.29x28 VdWContact
LEU 40 NTc.Cm17 ARG 295 7.30x29 Hydrophobic
LEU 40 NTc.Cm17 ARG 295 7.30x29 VdWContact
LEU 40 NTc.Cm17 ASP 297 7.32x31 VdWContact
LEU 40 NTc.Cm17 VAL 298 7.33x32 Hydrophobic
LEU 40 NTc.Cm17 VAL 298 7.33x32 VdWContact
LEU 40 NTc.Cm17 ALA 299 7.34x33 Hydrophobic
TYR 41 NTc.Cm16 GLN 45 1.24x24 VdWContact
TYR 41 NTc.Cm16 ASP 46 1.25x25 HBDonor
TYR 41 NTc.Cm16 ASP 46 1.25x25 Hydrophobic
TYR 41 NTc.Cm16 ASP 46 1.25x25 VdWContact
TYR 41 NTc.Cm16 VAL 298 7.33x32 Hydrophobic
TYR 42 NTc.Cm15 GLN 45 1.24x24 VdWContact
TYR 42 NTc.Cm15 VAL 298 7.33x32 Hydrophobic
TYR 42 NTc.Cm15 VAL 298 7.33x32 VdWContact
THR 43 NTc.Cm14 GLN 45 1.24x24 HBAcceptor
ARG 44 NTc.Cm13 GLN 204 45.51x51 HBDonor
ARG 44 NTc.Cm13 GLN 204 45.51x51 VdWContact
GLN 46 NTc.Cm11 GLN 204 45.51x51 HBAcceptor
GLN 46 NTc.Cm11 GLN 204 45.51x51 VdWContact
LEU 47 NTc.Cm10 ASP 195 - VdWContact
LEU 47 NTc.Cm10 ARG 197 - VdWContact
LEU 48 NTc.Cm9 ASP 195 - Hydrophobic
LEU 48 NTc.Cm9 ASP 195 - VdWContact
LEU 48 NTc.Cm9 GLU 196 - Hydrophobic
SER 49 NTc.Cm8 HIS 193 - VdWContact
SER 49 NTc.Cm8 HIS 194 - VdWContact
SER 49 NTc.Cm8 ASP 195 - HBAcceptor
SER 49 NTc.Cm8 ASP 195 - HBDonor
SER 49 NTc.Cm8 ASP 195 - VdWContact
SER 49 NTc.Cm8 ALA 200 - HBDonor
SER 49 NTc.Cm8 ALA 200 - VdWContact
SER 49 NTc.Cm8 HIS 202 - VdWContact
TRP 50 NTc.Cm7 ASP 195 - HBDonor
TRP 50 NTc.Cm7 ASP 195 - Hydrophobic
TRP 50 NTc.Cm7 ASP 195 - VdWContact
TRP 50 NTc.Cm7 ARG 197 - Hydrophobic
TRP 50 NTc.Cm7 ARG 197 - VdWContact
TRP 50 NTc.Cm7 LEU 198 - Hydrophobic
TRP 50 NTc.Cm7 LEU 198 - VdWContact
TRP 50 NTc.Cm7 HIS 202 - Hydrophobic
TRP 50 NTc.Cm7 HIS 202 - VdWContact
GLY 55 NTc.Cm2 GLN 45 1.24x24 VdWContact
ASN 56 NTc.Cm1 PRO 42 - Hydrophobic
ASN 56 NTc.Cm1 PRO 42 - VdWContact
ASN 56 NTc.Cm1 GLN 45 1.24x24 HBAcceptor
ASN 56 NTc.Cm1 GLN 45 1.24x24 Hydrophobic
ASN 56 NTc.Cm1 GLN 45 1.24x24 VdWContact
LYS 57 CX.1 PRO 44 - Hydrophobic
LYS 57 CX.1 PRO 44 - VdWContact
GLN 62 cxb1.5 PRO 42 - Hydrophobic
GLN 62 cxb1.5 PRO 42 - VdWContact