Predicted complex interactions

CXCL4_HUMAN + CXCR4

SUMMARY
Chemokine
CXCL4_HUMAN View chemokine entry
Chemokine organism
Homo sapiens
Partner
CXCR4 View partner entry
Partner description
UniProt: P61073; Gene: cxcr4_human; Family: Chemokine
Interactions detected
108

3D VIEW
Powered by NGL viewer
Model confidence legend
  • Very high confidence (pLDDT > 90)
  • High confidence (70 ≤ pLDDT < 90)
  • Low confidence (50 ≤ pLDDT < 70)
  • Very low confidence (pLDDT < 50)
RESIDUE CONTACTS

Residues are ordered by chemokine position and interaction type. Use the viewer controls to highlight contacting residues.

Download contacts (CSV)
Chemokine residue CCN Partner residue GPCRdb generic Interaction
ASP 7 NTc.Cm34 SER 18 - HBAcceptor
ASP 7 NTc.Cm34 SER 18 - VdWContact
GLN 9 NTc.Cm32 GLU 15 - HBDonor
GLN 9 NTc.Cm32 GLU 15 - VdWContact
GLN 9 NTc.Cm32 MET 16 - VdWContact
GLN 9 NTc.Cm32 GLY 17 - HBAcceptor
GLN 9 NTc.Cm32 GLY 17 - VdWContact
LEU 11 NTc.Cm30 MET 16 - Hydrophobic
LEU 11 NTc.Cm30 MET 16 - VdWContact
LEU 11 NTc.Cm30 TYR 21 - VdWContact
CYS 12 NTc.Cm29 TYR 21 - VdWContact
VAL 13 NTc.Cm28 ASP 20 - VdWContact
VAL 13 NTc.Cm28 TYR 21 - VdWContact
LYS 14 NTc.Cm27 ASP 20 - Cationic
LYS 14 NTc.Cm27 ASP 20 - HBDonor
LYS 14 NTc.Cm27 ASP 20 - VdWContact
LYS 14 NTc.Cm27 ASP 22 - Cationic
LYS 14 NTc.Cm27 ASP 22 - HBDonor
LYS 14 NTc.Cm27 ASP 22 - Hydrophobic
LYS 14 NTc.Cm27 ASP 22 - VdWContact
LYS 14 NTc.Cm27 SER 23 - VdWContact
THR 15 NTc.Cm26 MET 24 - Hydrophobic
THR 15 NTc.Cm26 MET 24 - VdWContact
SER 17 NTc.Cm24 LYS 25 - VdWContact
SER 17 NTc.Cm24 GLU 26 - HBDonor
SER 17 NTc.Cm24 GLU 26 - VdWContact
SER 17 NTc.Cm24 PRO 27 - VdWContact
SER 17 NTc.Cm24 CYS 28 - HBAcceptor
SER 17 NTc.Cm24 CYS 28 - VdWContact
GLN 18 NTc.Cm23 LYS 25 - HBAcceptor
GLN 18 NTc.Cm23 LYS 25 - Hydrophobic
GLN 18 NTc.Cm23 LYS 25 - VdWContact
GLN 18 NTc.Cm23 ARG 30 1.24x24 HBAcceptor
GLN 18 NTc.Cm23 ARG 30 1.24x24 VdWContact
GLN 18 NTc.Cm23 ILE 265 6.61x61 Hydrophobic
GLN 18 NTc.Cm23 ILE 265 6.61x61 VdWContact
GLN 18 NTc.Cm23 GLN 272 - VdWContact
GLN 18 NTc.Cm23 GLU 277 7.28x27 VdWContact
ARG 20 NTc.Cm21 ARG 30 1.24x24 VdWContact
ARG 20 NTc.Cm21 ASP 262 6.58x58 Cationic
ARG 20 NTc.Cm21 ASP 262 6.58x58 HBDonor
ARG 20 NTc.Cm21 ASP 262 6.58x58 VdWContact
ARG 20 NTc.Cm21 HIS 281 7.32x31 CationPi
PRO 21 NTc.Cm20 PHE 29 - Hydrophobic
PRO 21 NTc.Cm20 PHE 29 - VdWContact
PRO 21 NTc.Cm20 ARG 30 1.24x24 VdWContact
ARG 22 NTc.Cm19 ASP 97 2.63x63 Cationic
ARG 22 NTc.Cm19 ASP 97 2.63x63 HBDonor
ARG 22 NTc.Cm19 ASP 97 2.63x63 VdWContact
ARG 22 NTc.Cm19 ILE 185 - Hydrophobic
ILE 24 NTc.Cm17 ALA 180 - VdWContact
THR 25 NTc.Cm16 SER 178 - VdWContact
THR 25 NTc.Cm16 GLU 179 - VdWContact
THR 25 NTc.Cm16 ALA 180 - VdWContact
LEU 27 NTc.Cm14 ILE 4 - Hydrophobic
LEU 27 NTc.Cm14 ILE 4 - VdWContact
LEU 27 NTc.Cm14 ILE 6 - VdWContact
GLU 28 NTc.Cm13 TYR 7 - Hydrophobic
VAL 29 NTc.Cm12 ILE 6 - Hydrophobic
VAL 29 NTc.Cm12 ILE 6 - VdWContact
VAL 29 NTc.Cm12 THR 8 - VdWContact
ILE 30 NTc.Cm11 SER 9 - VdWContact
LYS 31 NTc.Cm10 THR 8 - Hydrophobic
LYS 31 NTc.Cm10 THR 8 - VdWContact
LYS 31 NTc.Cm10 SER 9 - VdWContact
LYS 31 NTc.Cm10 ASN 11 - VdWContact
GLY 33 NTc.Cm8 ASN 11 - HBAcceptor
GLY 33 NTc.Cm8 ASN 11 - VdWContact
PRO 34 NTc.Cm7 ASN 11 - VdWContact
PRO 34 NTc.Cm7 TYR 12 - Hydrophobic
HIS 35 NTc.Cm6 ASN 11 - HBDonor
HIS 35 NTc.Cm6 ASN 11 - VdWContact
HIS 35 NTc.Cm6 TYR 12 - HBDonor
HIS 35 NTc.Cm6 TYR 12 - VdWContact
HIS 35 NTc.Cm6 THR 13 - VdWContact
CYS 36 NTc.Cm5 ASN 11 - HBAcceptor
CYS 36 NTc.Cm5 ASN 11 - VdWContact
LYS 46 cxb1.5 ILE 185 - VdWContact
LYS 46 cxb1.5 ASP 187 45.51x51 Cationic
LYS 46 cxb1.5 ASP 187 45.51x51 HBDonor
LYS 46 cxb1.5 ASP 187 45.51x51 VdWContact
LYS 46 cxb1.5 PHE 189 - Hydrophobic
LYS 46 cxb1.5 PHE 189 - VdWContact
ASN 47 cxb1.6 PHE 189 - Hydrophobic
ASN 47 cxb1.6 PHE 189 - VdWContact
ASN 47 cxb1.6 TYR 190 - HBDonor
ASN 47 cxb1.6 TYR 190 - VdWContact
ARG 49 cxb1.10 PRO 191 - VdWContact
ARG 49 cxb1.10 ASP 193 5.32x33 Cationic
ARG 49 cxb1.10 ASP 193 5.32x33 HBDonor
ARG 49 cxb1.10 ASP 193 5.32x33 VdWContact
ASP 54 B1.1 PRO 27 - Hydrophobic
ALA 57 B1.4 PRO 27 - Hydrophobic
ALA 57 B1.4 PRO 27 - VdWContact
PRO 58 B1.5 GLU 26 - VdWContact
LEU 59 B1.6 PRO 27 - Hydrophobic
LEU 59 B1.6 PRO 27 - VdWContact
LEU 59 B1.6 CYS 28 - VdWContact
LEU 59 B1.6 PHE 29 - Hydrophobic
LEU 59 B1.6 PHE 29 - VdWContact
TYR 60 B1.7 PRO 27 - Hydrophobic
TYR 60 B1.7 PRO 27 - VdWContact
TYR 60 B1.7 PHE 29 - Hydrophobic
TYR 60 B1.7 PHE 29 - VdWContact
ILE 63 b1b2.7 ILE 4 - Hydrophobic
ILE 63 b1b2.7 PHE 29 - Hydrophobic
ILE 63 b1b2.7 PHE 29 - VdWContact
LEU 67 b1b2.12 ILE 6 - Hydrophobic