Predicted complex interactions

CXCL11_HUMAN + CXCR6

SUMMARY
Chemokine
CXCL11_HUMAN View chemokine entry
Chemokine organism
Homo sapiens
Partner
CXCR6 View partner entry
Partner description
UniProt: O00574; Gene: cxcr6_human; Family: Chemokine
Interactions detected
104

3D VIEW
Powered by NGL viewer
Model confidence legend
  • Very high confidence (pLDDT > 90)
  • High confidence (70 ≤ pLDDT < 90)
  • Low confidence (50 ≤ pLDDT < 70)
  • Very low confidence (pLDDT < 50)
RESIDUE CONTACTS

Residues are ordered by chemokine position and interaction type. Use the viewer controls to highlight contacting residues.

Download contacts (CSV)
Chemokine residue CCN Partner residue GPCRdb generic Interaction
PHE 1 NTc.Cm29 LEU 106 3.29x29 Hydrophobic
PHE 1 NTc.Cm29 LEU 106 3.29x29 VdWContact
PHE 1 NTc.Cm29 TYR 109 3.32x32 Hydrophobic
PHE 1 NTc.Cm29 TYR 109 3.32x32 VdWContact
PHE 1 NTc.Cm29 THR 110 3.33x33 Hydrophobic
PHE 1 NTc.Cm29 THR 110 3.33x33 VdWContact
PHE 1 NTc.Cm29 GLN 166 4.60x61 Hydrophobic
PHE 1 NTc.Cm29 GLN 166 4.60x61 VdWContact
PHE 1 NTc.Cm29 TYR 182 45.52x52 Hydrophobic
PHE 1 NTc.Cm29 PHE 247 6.51x51 Hydrophobic
PHE 1 NTc.Cm29 PHE 247 6.51x51 VdWContact
PHE 1 NTc.Cm29 LYS 251 6.55x55 VdWContact
PHE 1 NTc.Cm29 GLU 274 7.39x38 Cationic
PHE 1 NTc.Cm29 GLU 274 7.39x38 VdWContact
PHE 1 NTc.Cm29 TYR 278 7.43x42 HBDonor
PHE 1 NTc.Cm29 TYR 278 7.43x42 VdWContact
PRO 2 NTc.Cm28 TRP 87 2.60x60 Hydrophobic
PRO 2 NTc.Cm28 TRP 87 2.60x60 VdWContact
PRO 2 NTc.Cm28 LEU 106 3.29x29 Hydrophobic
PRO 2 NTc.Cm28 TYR 278 7.43x42 VdWContact
MET 3 NTc.Cm27 TYR 182 45.52x52 Hydrophobic
MET 3 NTc.Cm27 TYR 182 45.52x52 VdWContact
MET 3 NTc.Cm27 LYS 251 6.55x55 Hydrophobic
PHE 4 NTc.Cm26 LYS 251 6.55x55 Hydrophobic
PHE 4 NTc.Cm26 ARG 254 6.58x58 PiCation
PHE 4 NTc.Cm26 ARG 254 6.58x58 VdWContact
LYS 5 NTc.Cm25 TRP 87 2.60x60 VdWContact
LYS 5 NTc.Cm25 ALA 90 2.63x63 HBDonor
LYS 5 NTc.Cm25 ALA 90 2.63x63 VdWContact
LYS 5 NTc.Cm25 GLY 91 2.64x64 HBDonor
LYS 5 NTc.Cm25 GLY 91 2.64x64 VdWContact
LYS 5 NTc.Cm25 ILE 179 - Hydrophobic
LYS 5 NTc.Cm25 ILE 179 - VdWContact
ARG 6 NTc.Cm24 ILE 179 - VdWContact
ARG 6 NTc.Cm24 TYR 261 7.26x25 HBDonor
ARG 6 NTc.Cm24 TYR 261 7.26x25 VdWContact
ARG 6 NTc.Cm24 HIS 267 7.32x31 CationPi
ARG 6 NTc.Cm24 HIS 267 7.32x31 VdWContact
GLY 7 NTc.Cm23 LEU 175 - VdWContact
GLY 7 NTc.Cm23 ASP 176 - VdWContact
ARG 8 NTc.Cm22 HIS 23 - HBAcceptor
ARG 8 NTc.Cm22 HIS 23 - VdWContact
ARG 8 NTc.Cm22 LEU 27 1.28x28 Hydrophobic
ARG 8 NTc.Cm22 LEU 27 1.28x28 VdWContact
ARG 8 NTc.Cm22 ASP 176 - Cationic
ARG 8 NTc.Cm22 ASP 176 - HBDonor
ARG 8 NTc.Cm22 ASP 176 - VdWContact
ARG 8 NTc.Cm22 LYS 177 - Hydrophobic
ARG 8 NTc.Cm22 LYS 177 - VdWContact
CYS 9 NTc.Cm21 ASP 176 - HBDonor
CYS 9 NTc.Cm21 ASP 176 - VdWContact
LEU 10 NTc.Cm20 HIS 23 - Hydrophobic
LEU 10 NTc.Cm20 ALA 262 7.27x26 VdWContact
LEU 10 NTc.Cm20 HIS 267 7.32x31 Hydrophobic
ILE 12 NTc.Cm18 LEU 175 - Hydrophobic
ILE 12 NTc.Cm18 ASP 184 5.31x32 VdWContact
ILE 12 NTc.Cm18 TYR 261 7.26x25 Hydrophobic
VAL 16 NTc.Cm14 TRP 258 - Hydrophobic
VAL 21 NTc.Cm9 GLU 8 - VdWContact
VAL 21 NTc.Cm9 TYR 10 - Hydrophobic
VAL 21 NTc.Cm9 PHE 12 - Hydrophobic
VAL 21 NTc.Cm9 PHE 12 - VdWContact
ILE 24 NTc.Cm6 PHE 12 - Hydrophobic
ILE 24 NTc.Cm6 PHE 12 - VdWContact
LYS 26 NTc.Cm4 SER 14 - VdWContact
LYS 26 NTc.Cm4 ASN 16 - HBDonor
LYS 26 NTc.Cm4 ASN 16 - VdWContact
ALA 27 NTc.Cm3 PHE 15 - Hydrophobic
ALA 27 NTc.Cm3 PHE 15 - VdWContact
SER 28 NTc.Cm2 ASN 16 - VdWContact
SER 28 NTc.Cm2 SER 19 - HBAcceptor
SER 28 NTc.Cm2 SER 19 - VdWContact
ILE 29 NTc.Cm1 PHE 15 - Hydrophobic
MET 30 CX.1 GLN 20 - Hydrophobic
MET 30 CX.1 GLN 20 - VdWContact
MET 30 CX.1 HIS 23 - Hydrophobic
MET 30 CX.1 HIS 23 - VdWContact
TYR 31 CX.4 GLN 20 - HBDonor
TYR 31 CX.4 GLN 20 - VdWContact
ASN 35 cxb1.5 LEU 27 1.28x28 Hydrophobic
ILE 42 cxb1.15 ALA 262 7.27x26 Hydrophobic
LYS 49 B1.6 GLU 259 7.24x23 VdWContact
GLN 51 b1b2.4 GLU 259 7.24x23 HBDonor
GLN 51 b1b2.4 GLU 259 7.24x23 VdWContact
GLN 51 b1b2.4 ALA 262 7.27x26 Hydrophobic
GLN 51 b1b2.4 ALA 262 7.27x26 VdWContact
GLN 51 b1b2.4 MET 263 7.28x27 VdWContact
ARG 52 b1b2.6 TRP 258 - Hydrophobic
ARG 52 b1b2.6 TRP 258 - VdWContact
ARG 52 b1b2.6 GLU 259 7.24x23 Cationic
ARG 52 b1b2.6 GLU 259 7.24x23 VdWContact
GLN 60 b1b2.16 TYR 10 - Hydrophobic
GLN 60 b1b2.16 TYR 10 - VdWContact
LEU 63 B2.3 TYR 10 - Hydrophobic
ILE 64 B2.4 TYR 10 - Hydrophobic
ILE 64 B2.4 PHE 15 - Hydrophobic
LYS 67 b2b3.2 ASP 9 - Cationic
LYS 67 b2b3.2 ASP 9 - HBDonor
LYS 67 b2b3.2 ASP 9 - VdWContact
LYS 67 b2b3.2 TYR 10 - HBDonor
LYS 67 b2b3.2 TYR 10 - Hydrophobic
LYS 67 b2b3.2 TYR 10 - VdWContact
VAL 68 b2b3.3 PHE 15 - Hydrophobic
VAL 68 b2b3.3 PHE 15 - VdWContact